EasyManua.ls Logo

Brocade Communications Systems MLX Series - Chapter 6 Managing Routers and Modules; Managing the Device; Enabling and Disabling a DC Power Source; Disabling and Re-Enabling Power to Interface Modules

Brocade Communications Systems MLX Series
344 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Brocade MLX Series and NetIron XMR Hardware Installation Guide 223
53-1003821-01
Chapter
6
Managing Routers and Modules
Managing the device
You can perform these management tasks for the router:
Enable and disable a DC power source, if necessary.
Display status and temperatures of all hardware components.
Display the Syslog configuration and static and dynamic buffers.
Disable and re-enable power to interface modules.
Enabling and disabling a DC Power Source
To block the router from recognizing a DC power source (and as a result, enabling the device to
recognize an AC power source), enter the following command at the global CONFIG level of the CLI:
Brocade(config)# no use-dc-power
Syntax: no use-dc-power
Disabling and re-enabling power to interface modules
You can disable power and re-enable power to all interface modules, or to a specified interface
module using the power-off command in the CLI, as shown in the following example:
Brocade# power-off lp all
Syntax: power-off lp [all |<slot-number>]
all - disables power to all interface modules
slot-number - disables power to the interface module in the specified slot. You can specify 1-4
for 4-slot routers, 1-8 for 8-slot routers, 1-16 for 16-slot routers, and 1-32 for 32-slot routers.
NOTE
It is recommended that you do not disable power to interface modules during a software upgrade.
If you try to disable power during a software upgrade, the following message will be displayed:
Warning: There is an outstanding software download.
Do you want to continue ? (enter “y” or “n”)
Typen” and wait until the upgrade is complete.
To re-enable power to all interfaces or to a specific interface, enter the power-on lp command, as
shown in this example:
Brocade# power-on lp
Syntax: power-on lp [all |<slot-number>]
all - enables power to all interface modules

Table of Contents

Other manuals for Brocade Communications Systems MLX Series

Related product manuals