256 Brocade MLX Series and NetIron XMR Hardware Installation Guide
53-1003821-01
Using alarms to collect and monitor device status
6
Management and interface modules
When a management module or interface module is removed from the chassis, a major level alarm
is generated in the alarm history log. If the management module, interface module, or SFM is
powered off, a critical level alarm is generated in the alarm history log.
When a module is removed or powered off, alarms for all subsystems of the module are cleared
from the current alarm log. If a module is removed from the chassis, all alarms are cleared from the
current alarm log, and memory associated to its subsystems is freed. When a module is added to
the configuration, memory is reallocated.
To display all alarms in the alarm log related to
temperature information for a management
module
(where n, module number is 1-3 for MLX/XMR
and 1 for CER/CES)
and a specific fan
(where x, is the temperature device number).
show alarm [history] mp n temperature
[all |
x]
To display all alarms in the alarm log for all interface
modules and subsystems for the management
module.
show alarm [history] lp all
To display all alarms in the alarm log related to
a specific interface module
(where n, module number is 1-3 for MLX/XMR
and 1 for CER/CES)
and all alarms for it’s subsystems.
show alarm [history] lp n all
To display all alarms in the alarm log related to
subsystem information for an interface module
(where n, module number is 1-3 for MLX/XMR
and 1 for CER/CES)
and either all events on a specific subsystem,
or events for a particular subsystem
(where subsystem is
temperature or optic)
(where
x, is a the device number).
show alarm [history] lp n subsystem [all
|
x]
To display all alarms in the alarm log for all SFM and
subsystems for the SFM.
show alarm [history] sfm all
To display all alarms in the alarm log related to
a specific SFM
(where n, is SFM slot 1-8 for MLX/XMR)
and all alarms for it’s subsystems.
show alarm [history] sfm n all
To display all alarms in the alarm log related to
SFM information for a specific SFM
(where n, is SFM slot 1-8 for MLX/XMR)
and either all events on a specific subsystem,
or events for a particular subsystem
(where subsystem is
temperature or
fabric-element)
(where
x is 1-4 for a fabric element device
number).
show alarm [history] sfm n subsystem
[all |
x]
TABLE 42 Displaying alarm log information (Continued)
Description Syntax