256 Brocade MLX Series and NetIron XMR Hardware Installation Guide
53-1003821-01
Using alarms to collect and monitor device status
6
Management and interface modules
When a management module or interface module is removed from the chassis, a major level alarm
is generated in the alarm history log. If the management module, interface module, or SFM is
powered off, a critical level alarm is generated in the alarm history log.
When a module is removed or powered off, alarms for all subsystems of the module are cleared
from the current alarm log. If a module is removed from the chassis, all alarms are cleared from the
current alarm log, and memory associated to its subsystems is freed. When a module is added to
the configuration, memory is reallocated.
To display all alarms in the alarm log related to
temperature information for a management
module
(where n, module number is 1-3 for MLX/XMR
and 1 for CER/CES)
and a specific fan
(where x, is the temperature device number).
show alarm [history] mp n temperature
[all |
x]
To display all alarms in the alarm log for all interface
modules and subsystems for the management
module.
show alarm [history] lp all
To display all alarms in the alarm log related to
a specific interface module
(where n, module number is 1-3 for MLX/XMR
and 1 for CER/CES)
and all alarms for it’s subsystems.
show alarm [history] lp n all
To display all alarms in the alarm log related to
subsystem information for an interface module
(where n, module number is 1-3 for MLX/XMR
and 1 for CER/CES)
and either all events on a specific subsystem,
or events for a particular subsystem
(where subsystem is
temperature or optic)
(where
x, is a the device number).
show alarm [history] lp n subsystem [all
|
x]
To display all alarms in the alarm log for all SFM and
subsystems for the SFM.
show alarm [history] sfm all
To display all alarms in the alarm log related to
a specific SFM
(where n, is SFM slot 1-8 for MLX/XMR)
and all alarms for it’s subsystems.
show alarm [history] sfm n all
To display all alarms in the alarm log related to
SFM information for a specific SFM
(where n, is SFM slot 1-8 for MLX/XMR)
and either all events on a specific subsystem,
or events for a particular subsystem
(where subsystem is
temperature or
fabric-element)
(where
x is 1-4 for a fabric element device
number).
show alarm [history] sfm n subsystem
[all |
x]
TABLE 42 Displaying alarm log information (Continued)
Description Syntax

Table of Contents

Other manuals for Brocade Communications Systems MLX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems MLX Series and is the answer not in the manual?

Brocade Communications Systems MLX Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelMLX Series
CategoryNetwork Router
LanguageEnglish

Related product manuals