Forced card deletion
This feature allows you to remove a module conguration from the running conguration in interactive mode, while a dierent module is
inserted. Users should copy the conguration of the existing module (if applicable) before performing the following steps.
1. (Optional) Copy the running conguration of the existing module interfaces to a text editor, if the new module requires the
existing conguration. The conguration for the existing module will be automatically removed from the running conguration
after you enter the no module command as shown in the following steps.
2. Remove the existing module, and insert the new module.
The new module should come up in interactive state, and can be code synced at this time if needed.
3. Enter conguration mode.
4. Execute the following command:
device(config)#no module <slot> <module-type>
Example:
device(config)#no module 2 ni-mlx-8-port-10g-d
NOTE
This is best pulled directly from the running
conguration.
5. Answer "yes" to the prompt by pressing y .
6. Wait for the new module to come up.
7. Apply the appropriate conguration to the interfaces of the new module.
Verifying proper operation
Brocade NetIron MLXe Series Hardware Installation Guide
180 53-1004203-04

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems NetIron MLXe Series and is the answer not in the manual?

Brocade Communications Systems NetIron MLXe Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelNetIron MLXe Series
CategoryNetwork Router
LanguageEnglish

Related product manuals