5. Tighten the screws to secure the router in place. For extra support, use additional screws.
NOTE
For better grounding of the router to the rack, attach the router using star washers. You should also use star washers
with any single-hole grounding lugs to keep the lugs from rotating.
NOTE
When making the primary ground connection, use a star washer to prevent lug rotation.
Repeat step 2 through step 5 to mount each router in the rack.
Installing modules in a Brocade MLXe Series 16-slot router
The Brocade MLXe Series-16 router ships with the required switch fabric modules installed.
The installation sequence for multiple modules is important to ensure proper
t. Always ll the bottom slots in the Brocade MLXe
Series-16 router rst. Begin by lling the slots from the left side of the router, and work towards the right side. Refer to Brocade MLXe
Series-16 router components on page 23 for slot locations.
NOTE
Installation instructions are identical for interface, management, and switch fabric modules. However, there are specic
requirements and installation instructions for the following devices: For installing NI-MLX-1Gx48-T-A modules in the 16-slot
router., refer to the high-speed fan and software requirements documented in NIBI-16-FAN-EXH-A high-speed fan
assemblies on page 86 and NI-MLX-1Gx48-T-A interface module on page 70. For installing 2x100GbE interface modules,
refer to Installing 2x100GbE CFP2 interface modules in Brocade MLXe Series routers on page 90.For instructions about
installing BR-MLX-10Gx24-DM interface modules, refer to Installing BR-MLX-10Gx24-DM interface modules in Brocade
MLXe Series routers on page 91.
DANGER
The intra-building port or ports of the equipment or subassembly is suitable for connection to intra-building or unexposed
wiring or cabling only. The intra-building port or ports of the equipment or subassembly MUST NOT be metallically
connected to interfaces that connect to the outside plant (OSP) or its wiring. These interfaces are designed for use as
intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 5) and require isolation from
the exposed OSP cabling. The addition of Primary Protectors is not sucient protection in order to connect these
interfaces metallically to OSP wiring.
Router slot numbers into which you must install the modules are shown in the following table. Markings for the router slots appear at the
base of the slots.
TABLE 30 Brocade MLXe Series-16 module slot designations
Module Slot number
Management modules Active module - M1 (upper).Redundant module - M2 (lower).
Interface modules 1 - 16
Switch Fabric modules SF1 - SF4
NOTE
If you are installing a redundant management module, refer to the chapter titled "Using a Redundant Management Module" in
the Brocade NetIron MLX Series and Brocade NetIron Family Conguration Guide for information about how the redundant
module works, optional software congurations that you can perform, and how to manage the redundancy feature.
Installing a Brocade MLXe Series-16 router
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04 115

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems NetIron MLXe Series and is the answer not in the manual?

Brocade Communications Systems NetIron MLXe Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelNetIron MLXe Series
CategoryNetwork Router
LanguageEnglish

Related product manuals