T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 34 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Warning Codes without registration
Fork control, joystick R11
1. Check that the joystick for the fork operations has not stuck in
an actuated position.
2. Check that R11 is located in its bracket.
Check that there is no play or oxidisation on the connector
pins on terminal X11. The voltage on input 503 should be 3,7 +/
-0,6 VDC when R11 is correctly adjusted.
3. Calibration of fork joystick.
- Check that the joystick is not actuated and is in its neutral posi-
tion.
- Restart the truck.
4. Calibration of the joystick takes place. If the correct voltage is
on input 503 and calibration does not help, replace the A5
electronic card.
Code 21
Description Potentiometer R11 for fork lift/lower gives incorrect
voltage when ignition is switched on (+/-0.6 V).
Error mode Start up error
Error cause 1. Activated joystick at start up
2. Faulty potentiometer/wiring
3. Calibration error.
4. Defective electronic card A5
Comments Manoeuvre to neutral position
82
83
85
86
81
98
100
84
ELECTRONIC CARD
A5
505
506
510
202
208
204
205
301
503
504
X
X
X
INP. JOYSTICK FORK
INP. JOYSTICK REACH CARRIAGE
INP. JOYSTICK TILT
INP. JOYSTICK SPARE 1
INP. JOYSTICK SPARE 2
INP. WEIGHT
INP. OVERRIDE
INP. LIFT LIMIT SPECIAL HEIGHT
X33
X11
Ye
R
Gr
R11
X11
X11
X32
X32
28
27
Pg 6 4
Pg 6 4