Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 45
Electronic card – 5710
Warning Codes without registration
1. Check that the ventilation is okay.
2. Check the fan M12, by the motor regulators.
3. If the ventilation okay, replace A2.
1. Replace the lift regulator A2.
Code 46
Description Warning temperature in the lift regulator
Error mode Maximum current reduced
Error cause 1.Overheated lift converter
2. Defective fan
3.Defective lift regulator, A2
Comments
Code 47
Description Current calibration error in the lift regulator
Error mode No corrective action
Error cause 1. Defective frequency converter
Comments