EasyManua.ls Logo

BT REFLEX RR B7-8C - Page 275

BT REFLEX RR B7-8C
514 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 63
Electronic card – 5710
Warning codes with registration
Mast reach/retraction control, joystick R12
1. Check that R12 is located in its bracket.
- Check that the voltage across R12 (yellow and grey cable) is 7-
7.5 VDC.
- Check that there is no play or oxidisation on the connector pins
on terminal X11.
- The voltage on input 504 should be 3.7 +/-0.6 VDC when R11 is
correctly adjusted.
2. If the correct voltage is on input 504 and the fault remains, re-
place the A5 electronic card.
Code 92
Description Potentiometer R12 for mast reach in/out movement
gives incorrect voltage (<0.3 or >7.0
V)
Error mode General error
Error cause 1. Faulty potentiometer/wiring or activated input with-
out connected potentiometer
2. Defective electronic card A5
Comments
https://www.forkliftpdfmanuals.com/

Table of Contents