T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 64 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Warning codes with registration
Extra hydraulic functions, joystick R14 and R15
1. If a valve is not connected, parameter 15/16 must be set to 0.
Check parameter 16 as follows. See the section “Parameter
setting” in this manual.
2. Check whether the two joysticks used for the optional hydrau-
lic function have become stuck in the actuated position.
3. Check that R14 and R15 are located in their brackets.
Check that there is no play or oxidisation on the connector
pins on terminal X11. The voltage on input 506 and 510 should
be 3.7 +/-0.6 VDC when R14 and R15 are correctly adjusted.
4. If the correct voltage is on inputs 506 and 510, replace the A5
electronic card.
Code 93
Description Potentiometer R14 or R15 for extra function “1“ and
“2“ gives incorrect voltage (<0.3 or >7.0
V).
Error mode General error
Error cause 1. Parameters 15/16 >0, no potentiometer connected
2. Faulty potentiometer/wiring
3. Defective electronic card A5