Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 93
Electronic card – 5710
Error Codes
Temperature sensor B2 in the pump motor
1. Check that the ventilation is okay, especially the fan M10 in the
motor compartment.
Code 213 - 214
Description CAN fault on the drive regulator
Error mode Drive regulator error
Error cause 1. Defective drive regulator, A1
Comments
Code 223
Description CPU or memory fault on the lift regulator
Error mode Lift regulator error
Error cause 1. Defective lift regulator, A2
Comments
Code 225
Description Overheated pump motor
Error mode Lift regulator error
Error cause 1. Motor heavily loaded
2. Faulty wiring/temperature sensor
Comments Restart possible