T-code Valid from serial number
403-414, 669-671, 716-718 713962-
Date Order number
2005-06-01 218920-040
24- 96 Service Manual REFLEX RR B/E, RR B/E CC © BT Europe AB
Electronic card – 5710
Error Codes
Battery circuit
1. Check that the battery is okay, sufficiently charged and of the
right model.
2. Check the contactor points on K10.
3. If everything is okay, replace A2.
Code 229 - 230
Description Too high voltage on lift regulator
Error mode Lift regulator error
Error cause 1. Defective battery
2. Poor contact at K10’s contactor points
3. Defective lift regulator, A2
Comments