Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 97
Electronic card – 5710
Error Codes
Main contactor, K10
1. If you forget to switch off the truck and pull out the charging
plug an error code is given.
2. Check that no extra equipment overloads the electrical sys-
tem.
3. Check that there is 48 VDC on input 808, cable 23 when K10 is
activated. If not, check the fuse F62 (10 A), contactor points on
K10 and the cables 1, 8 and 23.
4. If this does not help, replace A2.
5. Replace A5.
Code 231 - 232
Description Too low voltage on lift regulator
Error mode Lift regulator error
Error cause 1. Faulty wiring/fuse F62
2. External current load incorrectly connected
3. Charger plug removed with ignition key switched
on
4. Defective electronic card A5
5. Defective lift regulator, A2
Comments