SMART KTF 2000 – KTF/100HP Operation
3A-30 SMART KTF 2000
MODIFY - Modifying Article Parameters
SETUP
MODIFY
This function allows modifying one or more parameters of an existing article and saving the
changes without changing the article name.
The parameters that you can modify with this function are the same parameters that you can
directly modify on each KTF/100HP device within the P1, P2 and P3 programming levels,
i.e.:
SMART
Parameter
KTF
Parameter
MEANING KTF
LEV.
1) MAIN TENSION
2) ERR TENSION
3) TIME ALARM
4) IN-DE TENSION
MAIN * TENSION
ERROR TENSION
TIME ALARM
INC-DEC TENSION
Control tension
Tolerance beyond which an Error occurs
Time period for which the tension may run
out of tolerance
Tension of INC/DEC graduation
P1
5) EXIT TENSION
6) RELAX TENSION
7) RELAX SPEED
EXIT * TENSION
RELAX TENSION
RELAX SPEED
Device tension with machine standstill
Yarn relaxation tension
Activation speed of yarn relaxation
P2
8) MODE
MODE Operating modes of INC/DEC commands
P3
The modified article with the associated control parameters will be saved to the SMART
KTF 2000 Data Base.
Using the LOAD function, it will then be possible to update the KTF devices involved by the
modifications.
For a detailed explanation of each individual parameter and related examples, please
refer to KTF/100HP Manual, Chapter 3.
From the SETUP menu, press
until the >MODIFY menu option is selected.
At this point, press
to access the function..
This screen allows you to select the article to be modified from the SMART KTF
2000 database.
Select the desired article using
, .
Press
to start the article modification procedure.

Table of Contents