14
Technical data
Type ME43
6.9 CC-Link specications
Features
Remote I/O Station only I/O points
Remote Device Station i/O points and Words
Congurablenumberofoccupied
stations
1...4
Congurablenumberofextension
cycles
1, 2, 4, or 8
Supported protocols CC-Link version 2.0
CC-Link version 1.11
CC-Linkversion2.0
Number of stations up to 4 occupied stations
Maximum number of input data 368 bytes
Maximum number of output data 368 bytes
Input data 112 bytes (RY) and 256 bytes (RWw)
Output data 112 bytes (RX) and 256 bytes (RWr)
Extension cycles 1, 2, 4, 8
Transmission speed 156 kBit/s, 625 kBit/s, 2500 kBit/s, 5 MBit/s, 10 MBit/s
CC-Linkversion1.1and2.0
Number of stations up to 4 occupied stations
Maximum number of input data 48 bytes
Maximum number of output data 48 bytes
Input data 4 bytes (RY) and 8 bytes (RWw) per occupied station
Output data 4 bytes (RX) and 8 bytes (RWr) per occupied station
Transmission speed 156 kBit/s, 625 kBit/s, 2500 kBit/s, 5 MBit/s, 10 MBit/s