CAB A Series - ESC. Start and Stop Value for Binary Data

CAB A Series
263 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
cab Produkttechnik GmbH & Co KG 31
31
[TABLE OF CONTENTS]
[COMMAND LIST][INDEX]
Hermes
Apollo
A-series
This
function is
available
for:
[ESC][i][L][S]
PRODUCT MARKING AND BARCODE IDENTIFICATION
M-series
ESC. Start and stop value for binary data
Start and Stop value for binary data.
ESC.
To transmit binary data -such as graphics or fonts etc. - it is highly recommended to use this method
of data transmission. All ESC characters in a binary file have to be replaced by a double ESC
(ESCESC) to avoid unexpected reactions by the printer.
A binary constellation- for example- which contains ESC c would be interpreted as "CANCEL JOB" as
soon as it is received by the printer. Therefore alll ESC characters should be exchanged.
A help tool is available on the internet.
You may do a free download of the tool: DOWNLOAD.EXE from our website at:
http://www.cabgmbh.com.
This can also be done more comfortable with the "cab cardmanager" which is not free of charge.