ACCESS CONTROL
1 2 3 3P 4 7
S1 GND
R700 / R800
A-B
S1-GND
1-2 2-3 2-3P 2-4 2-7
A B
AF43S
AF868
TOP-A433N
TOP-4862N
p. 21 - Manual FA01274-EN - 11/2018 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. Original instructions
Command and control devices
(R700/R800) R700 card for using the transponder selector or card reader, or, R800 card for using the keypad
selector.
Set the type of selector when programming.
(S1-GND) LT001 transponder selector or card reader
(A-B) Keypad selector.
(1-2) STOP button (NC contact). For stopping the gate while excluding automatic closing. To resume movement
either press the control button or any other control device.
Turn on the [Total Stop] function when programming. If the button is unused, leave this function off.
(2-3) OPEN ONLY function from control device with NO contact.
In MAINTAINED ACTION mode you must connect the control device onto 2-3.
(2-3P) PARTIAL OPENING feature from command device (NO contact).
(2-4) ONLY CLOSE function from control device (NO contact).
In MAINTAINED ACTION mode, the control device must be connected to 2-4.
(2-7) OPEN-CLOSE-INVERT (step-step) function from control device (NO contact). Alternatively, when
programming on [Command 2-7], turn on the OPEN-STOP-CLOSE-STOP (sequential) command.
(AF43S/AF868) Plug-in radio-frequency card for controlling the gate via a transmitter.
(TOP-A433N/A862N) Antenna with TOP-RG58 cable for remote control of the gate.