p. 35 - Manual FA01274-EN - 11/2018 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. Original instructions
Times
[Automatic Cls.] function ➡ [O ] > [1 sec.] > ... > [180 sec.]
The wait before the automatic closing starts once the opening limit-switch point is reached. The automatic
closing does not work if any of the safety devices trigger when an obstruction is detected, or after a total stop, or
during a power outage.
[Automatic partially close] ➡ [O ] > [1 sec.] > ... > [180 sec.]
The wait before the automatic closing starts after a partial opening command, and for a preset time.
The automatic closing does not work if any of the safety devices trigger when an obstruction is detected, or after
a total stop, or during a power outage.
Manage lights
[Gate open warning light] ➡ [Warning light on] > [Warning light fl ashing]
Configure the warning light connected to contact 10-5 as: [Warning light on] = to show the gate is open or
moving [Warning light fl ashing] = to show that the gate is moving, it stays on when the gate is open.
[Light on E3] ➡ [Disabled]: > [Cycle light] > [Courtesy light]
Configure the light connected to contact 10-E3 as: [Cycle light] = it stays on from the moment the gate starts
opening until itis completely closed (including the automatic closing time). If the automatic closing is not on, the
light stays off, [Courtesy light] = it turns on from the moment the gate starts opening until the opening limit-
switch is reached,and stays on for the set time, see [Courtesy time].
[Courtesy time] ➡ [60 sec.] > ... > [180 sec.]
To set the courtesy light turn-on time after a complete opening maneuver.
[Pre-fl ashing time] ➡ [O ] > [1 sec.] > ... > [10 sec.]
After an open or close command, the fl ashing light connected to 10-E fl ashes for a preset time before starting
the maneuver.
Functions
[Maintained action] ➡ [O ] > [On]
The gate opens and closes by keeping the button pressed. Opening button on contact 2-3 and closing button on
contact 2-4. All other control devices, even radio-based ones, are excluded.
[Output B1-B2] ➡ [Bistable] > [Monostable 1 sec.] > ... > [Monostable 180 sec.]
To confi gure the B1-B2 contact in Bistable mode (switch) or Monostable mode (the contact stays closed between
1 and 180 secs.).
[Remove obstruction] ➡ [O ] > [On]
When this function is on and an obstruction detected by the sensitive safety-edge, the control board inverts the
movement to give enough space to remove said obstruction. When this function is o , the movement is inverted
until the gate reaches the limit-switch.