5–27 62-11640
DIESEL MAX GEN AMPS 22A
10 TO 35 in 0.5A incre-
ments
Indicates to the microprocessor the maximum allow-
able amperage in Diesel operation.
USE FACTORY DEFAULT SETTING ONLY. DO
NOT OPERATE UNIT WITH DIFFERENT SETTING.
STARTUP MAX GEN AMPS 17A
10 TO 35
in 0.5A increments
Indicates to the microprocessor the maximum allow-
able amperage during start up.
USE FACTORY DEFAULT SETTING ONLY. DO
NOT OPERATE UNIT WITH DIFFERENT SETTING.
DIESEL OFFSET MAX AMPS 4A
0 TO 10
in 0.5A increments
The maximum allowable amperage in low speed op-
eration will be the configured MAX GEN AMPS or
MAX STANDBY AMPS less this value.
USE FACTORY DEFAULT SETTING ONLY, DO
NOT OPERATE UNIT WITH DIFFERENT SETTING.
COMP RESTART OFFSET 0.2 − 1.0°C in 0.1
deg increments
In Continuous Run and when difference between
ambient and setpoint is < 105°C, use the COMP RE-
START OFFSET configuration value for the switch
point to turn cool on (instead of 0.25°C). If the ambi-
ent and setpoint are more than 105°C then the switch
point remains 0.25°C
NUMBER OF COMM MODULES 0 – Not Installed
1 – 1 Optional
Comm Module Installed
If set to 1, this enables alarm 26200 CAN Communi-
cation failure.
NUMBER OF REMOTE PANELS 0 – Not Installed
1 – 1 Remote
Panel Installed
If set to 1, this enables Alarm 20101, CAN Commu-
nication failure with Remote Panel.
If set to 0 and a remote panel is connected, the re-
mote panel will display a message indicating that the
configuration must be changed and will not operate
until then.
NOTE
If set to 1, and number of comm modules
is set to 0, the number of comm modules
is automatically increased to 1 on the
main micro. A remote panel will not be
operable without a comm module.
AUTO FRESH AIR SETTINGS
AUTOFRESH AIR NOT INSTALLED
STANDARD
NOT INSTALLED = AutoFresh Air Exchange is not
installed.
STANDARD = AutoFresh Air Exchange is installed.
AUTOFRESH AIR DELAY SETPOINT
0-48 HOURS IN
1 HOUR
INCREMENTS
SETPOINT - Once the compartment temperature
has reached setpoint 1.5°F (0.8°C), the Auto- Fresh
Air Exchange will start to operate based on the se-
lected Functional Parameters.
0 to 48 Hours - After this length of time, AutoFresh Air
Exchange will begin if the unit is no longer running in
Pulldown, even though the compartment tempera-
ture may not have reached setpoint.
Table 5–1 Configuration Settings
(Refer to Section 5.2.3 for instructions on entering Configuration settings)
Configuration Selections Description

Table of Contents

Other manuals for Carrier TRANSICOLD Vector 8500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier TRANSICOLD Vector 8500 and is the answer not in the manual?

Carrier TRANSICOLD Vector 8500 Specifications

General IconGeneral
BrandCarrier TRANSICOLD
ModelVector 8500
CategoryAutomobile Accessories
LanguageEnglish

Related product manuals