62-11640 6–4
TECHNICIAN RESET REQUIRED
(AL00021)
Alarm 00011 CHECK ENGINE OIL PRESSURE or 00012 HIGH
COOLANT TEMPERATURE has been activated three times in the last
two hours and the unit has been locked out. Refer to Section 7 for fur-
ther information.
TIME SELECTION NOT CHANGED A time change was started but not entered (saved) in Configuration
List.
TRIP START ENTERED The Trip Start marker has been placed in the DataLink data
recorder.
UNIT BATTERY TOO LOW The unit battery has dropped below 7 volts for more than 10 seconds.
UNIT SHUTDOWN − DOOR OPEN The unit has shutdown because the refrigerated compartment door
is open.
UNIT SHUTDOWN − PRESS ALARM
KEY
An active shutdown alarm has shut the unit down.
UNIT SHUTDOWN − REMOTE SWITCH
1
The unit has shutdown because switch is open. May be connected
to a door or a remote control switch.
USE UP/DOWN KEY TO SCROLL
USE = KEY TO SELECT ITEM TO
CHANGE
Items available are being displayed or additional items are available
for selection. Use the up or down arrow key to highlight or display
and highlight the desired selection and then use the “=” key to select
it.
VIEWING MENU SOFTKEY SELEC-
TIONS PRESS MENU KEY TO SCROLL
Additional soft key selections are available and the MENU key is to
be used to scroll and view them.
WARNING: NO TEMP CONTROL The temperature sensors have failed and the unit has entered
Cargo Protect Mode. Refer to Section 4.11.2.
Table 6–1 MessageCenter Messages
Message Description