6-MAINTENANCE
Fluidsandlubricants
SystemQuantity
Fluid
CASECON-
STRUCTION
specication
Reference
specication
Fueltank
20L
(5.3USgal)
ASTMD975
EN590
CASEAKCELANO.1™ENGINEOIL
CI-4SAE15W-40
Temperateclimates(****)
MS1121
SAE15W-40
ACEAE7/E5
APICI-4
Engineoil
3.7L(1.0US
gal)
CASEAKCELANO.1™ENGINEOIL
CI-4SAE10W-30
Coldclimates(***)
MS1121
SAE10W-30
ACEAE7/E5
APICI-4
Travel
reductionunit
0.33L(0.09US
gal)x2
CASEAKCELAGEARLUBE135HEP
80W-90
MAT3511
SAE80W90
APIGL-5
CASEAKCELAACTIFULL™
OTEXTENDEDLIFECOOLANT
CONCENTRATE(**)
MAT3624
GradeOAT-EG1
ASTMD6210
TYPEI-FF
Enginecoolant
3.5L(0.9US
gal)
CASEAKCELAACTIFULL™OT
EXTENDEDLIFECOOLANT
50/50PREMIXED
MAT3624
GradeOAT-EG2
ASTMD6210
TYPEIII-FF
CASEAKCELAHYDRAULICLL46
ISO6743-4L-HV
46Hydraulicoil
(ISO11158)
Hydraulicoil
tank(*)
13L
(3.4USgal)
BIODEGRADABLEOILISOVG46(*****)
ISO6743-4
L-HEES46(ISO
15380)
Grease
(Attachment)
CASEAKCELAMOLYGREASE
MAT3550
NLGI2
Grease(Swing
bearing)
CASEAKCELA251HEPMULTI-
PURPOSEGREASE
MAT3550
GradeA
NLGI2
(*)Thetotalcapacityofthehydraulicsystemis23L(6.1USgal).
(**)Concentrateantifreezetobemixed50/50withdistilled(deionized)water.
(***)Coldclimates-T emperatureoperatingrange:-2525°C(-1377°F)
(****)Temperateclimates-Temperatureoperatingrange:-1540°C(5104°F)
(*****)ForCASECONSTRUCTIONgenuinelubricatingoilpleasecontactCASECONSTRUCTIONdealers.
NOTICE:whenoperatingthemachineinambienttemperaturesoutsidetheabovementionedrange,consultyour
CASECONSTRUCTIONdealerforspecicmachineprovisionandforspecicuidsandlubricantstobeused.
NOTICE:usinganylubricatingoilsotherthanCASECONSTRUCTIONgenuineproductsmayleadtoadeterioration
ofperformanceandcausedamagetomajorcomponents.
NOTICE:donotmixCASECONSTRUCTIONgenuineoilwithanyotherlubricatingoilasitmayresultindemageto
thesystemsofmajorcomponents.
NOTICE:ifthemachinewasboughtlledwithmineralhydraulicoilandyouwanttochangetobiodegradablehydraulic
oil,thisoperationmustbecarriedoutbytheDealerpersonnel.Infact,itisnecessarytothoroughlydrainmineraloil
andushtheentirehydraulicsystem.Rememberthatmineralhydraulicoilmustnotbemixedwithbiodegradable
hydraulicoil.