6-MAINTENANCE
Startingupthemachineafterstorage
WARNING
Unexpectedmachinemovement!
Beforestartingtheengine,makesureallcontrolsareintheneutralposition.
Failuretocomplycouldresultindeathorseriousinjury.
W0311A
WARNING
Inhalationhazard!Risktooperatorsandbystanders.
Avoidrunningtheengineinconnedareas.Makesurethereisadequateventilationatalltimes.
Failuretocomplycouldresultindeathorseriousinjury.
W0156A
1.Drainthefueltankandcleanthefuellter.Replacethe
lterelementasrequired.
2.Fillthefueltankwithsuitablefuel.
3.Installthebatteriesorreconnectthecabletotheneg-
ative(-)terminal.
4.Greasethemachinethoroughly.
5.Checktheconditionofthefandrivebeltandreplaceit
ifnecessary.
6.Checktheconditionoftheairconditioningdrivebelt
andreplaceitifnecessary(ifequipped).
7.Checkthecoolingsystemlevelandaddmorecoolant
ifnecessary.
8.Checkthehydraulicuidlevel,andsupplyitasneces-
sary.
9.Checkthegearoillevelofthetravelreductiongear
andthatoftheswingreductiongear,andsupplyitas
necessary.
10.Cleanthecylinderrod.
11.Removethelidoftheaircleanerinletandthatofthe
exhaustpipe.
12.Removethe"Donotoperate"label,andstarttheen-
ginefollowingtheenginestartingprocedure.
13.Checkalltheindicatorsandlightscarefully.
NOTICE:checkthemachineandtheengineforleaksor
foranypartsthatarebroken,defectiveormissing.