6-MAINTENANCE
Every500hours
Radiatorandcoolers
CAUTION
Flyingdebris!
Compressedaircanpropeldirt,rust,etc.intotheair.Weareyeandfaceprotectionwhenusingcom-
pressedair.
Failuretocomplycouldresultinminorormoderateinjury.
C0049A
Cleantheradiatorevery500h
1.Stoptheengineandremovethestarterkey.
2.Opentheengineaccessdoor.
3.Visuallyinspecttheradiatorforcloggedradiatorns.
NOTICE:overheatmayoccuriftheradiatorn,ortheoil
coolernisclogged.
NOTE:afterworkinginadustyplace,cleanradiatormore
frequently.
4.Usecompressedairtoblowawaymudordirtthathave
cloggedtheradiatorn.Blowtheairintheopposite
directionofthefanairow.
NOTICE:inpresenceofgreasyoroilydust,consultyour
CASECONSTRUCTIONdealerinordertocarryoutaspe-
cialcleaningoperation.
NOTICE:usecompressedairpressureofmaximum
550kPa(79.8psi).
SMIL16MEX2526AB1
5.Visuallyinspecttheradiatorforbentorbrokenns.
6.Visuallyinspecttheradiatorforcoreandgasketleaks.
SMIL16MEX0431AA2
6-48