6-MAINTENANCE
Cleaningofthebattery
1.Washtheterminalwithhotwater,andapplygreaseto
theterminalsafterwashing.
SMIL16MEX2521AB2
Batteryvoltagecheck
NOTICE:ifthemachineistobeoperatedforashorttimewithoutbattery(usingaslavebatteryforstarting),use
additionalcurrent(lights)whileengineisrunningandinsulateterminalofbattery.Ifthisadviceisdisregarded,damage
toalternatorandregulatormayresult.
1.Stoptheengine.
2.Measurethevoltagewithacircuittesterbetween
thebatteryterminals.
3.Ifthebatteryvoltageislessthanthefactoryspec-
ication,checkthebatteryspecicgravityand
rechargethebattery.
Batteryvoltage:morethan12V
(1)Positiveterminal.
(2)Negativeterminal.
SMIL16MEX0771AB3
Replacementofthebattery
ForthebatteryreplacementrefertoyourCASECON-
STRUCTIONdealer.
6-38