MicroView 1.0 – User Manual – Version 1.9
37
Figure 17 – Scaling Screen
The following areas can be identified in the Scaling screen above.
•
– Press this button to select the device that needs to be scaled. Ensure that the
desired device remains selected.
• Travel Distance – The number in this field, also called Sensor Maximum Displacement,
is a pre-defined number, characteristic to each device. The number keypad underneath
this field should be used by the user to insert the given travel distance number for the
selected device.
•
– Press the button with the preferred type of measuring unit for the
scaling procedure only. The button turns yellow when selected. The scaling procedure
needs to be performed using one type of measuring units, not both. Please note that the
measuring unit selected on this screen does not affect the choice of measuring
units used during the regular operation of the MicroView unit.
• Minimum Value – The value that needs to be recorded in this field corresponds to the
minimum travel position of the selected device (e.g., maximum extended position for an
LVDT pin, or fully open position for a welding gun (LPT)). To record this value, set the
device in the minimum travel position and press the button underneath.
• Maximum Value – The value that needs to be recorded in this field corresponds to the
maximum travel position of the selected device (e.g., maximum retracted position for an
LVDT pin, or fully closed position for a welding gun (LPT)). To record this value, set the
device in the maximum travel position and press the button underneath.
• – Press this button to save the settings on the Scaling screen.
• – Press this button to exit the Scaling screen without saving the settings.