Resetting Passwords and Settings to Factory Defaults
If you have changed passwords on your MicroView and forgotten the passwords, or you need to
reset the unit to factory defaults, follow the instructions below.
1. Unplug the MicroView unit to turn it OFF.
2. Remove the four M3 flat head Phillips screws from the top of the MicroView enclosure.
3. Pull back the lid of the MicroView enclosure so that the electronics board is visible. Switch the
following DIP switches, based on what needs to be reset:
Reset User Password: 6-ON, 7-OFF, 8-OFF
Reset Maintenance Password: 6-OFF, 7-ON, 8-OFF
Reset to Factory Defaults: 6-ON, 7-ON, 8-ON
4. Turn the MicroView ON and let restart.
5. Once the unit gets to the Run screen, unplug again to disconnect power.
6. Reset switches 6, 7, 8 to the OFF position.
7. Re-attach the front cover of the MicroView unit and secure with the four screws.
8. Plug the unit to restart.