CDC-2000
操作手冊
Operational Manual
A) JJ :Slow mold-opening speed setup.
B) KK : Slow mold-opening pressure setup.
C) SS : Slow mold-opening counter-balance pressure setup.
D) LLLLL : Slow mold-opening end-position setup.
E) MM : Fast mold-opening speed setup.
F) NN : Fast mold-opening pressure setup.
G) TT : Fast mold-opening counter-balance pressure setup.
H) OOO.O : Fast mold-opening end-position setup.
I) PP : Decelerated mold-opening speed setup.
J) QQ : Decelerated mold-opening pressure setup.
K) UU :Decelerated mold-opening counter-balance pressure setup.
L) RRR.R :Decelerated mold-opening end-position setup.
M) hhh.h : Mold-opening time setup.
N) The descending order of the requirement for mold-opening switch position, setup
is : RRR.Rmm ≧ OOO.Omm ≧aaaa.amm ≧ LLLLLp ≧ IIIIIp.
2.5.4.5. Operational Description of Fast-Speed Mold Opening:
There are three phases for fast-speed mold-opening:
A) Fast-speed slow mold-opening as the first step to set up the force needed for
opening the molds. The parameter
“
KK
“
for pressure is to be set above 70%.
B) Fast-speed fast mold-opening 2
nd
step to quickly open the molds.
Either the standard mold-opening method or the hydraulic pressure loop
differentiated method, can be applied in this step. If you choose the hydraulic
pressure loop differentiated method, please move to
“
Function Selection
”
for
“
super fast mold-opening
”
so that mold-opening will speed up. However
“
MM
”
has
to be above 70% to execute first function.
C) Fast-speed decelerated mold-opening as the 3
rd
step.
04/08/13