Table 122: Modbus memory map: Status of digital inputs (Table 3)�
Status of digital inputs: Slot 3
Configuration variable Address Valid data window
Input Status 1 CD78 - CD79 0 to 1
Input Status 2 CD7A - CD7B 0 to 1
Input Status 3 CD7C - CD7D 0 to 1
Input Status 4 CD7E - CD7F 0 to 1
Input Status 5 CD80 - CD81 0 to 1
Input Status 6 CD82 - CD83 0 to 1
Input Status 7 CD84 - CD85 0 to 1
Input Status 8 CD86 - CD87 0 to 1
Table 123: Modbus memory map: Status of digital inputs (Table 4)�
Status of digital inputs: Slot 4
Configuration variable Address Valid data window
Input Status 1 D160 - D161 0 to 1
Input Status 2 D162 - D163 0 to 1
Input Status 3 D164 - D165 0 to 1
Input Status 4 D166 - D167 0 to 1
Input Status 5 D168 - D169 0 to 1
Input Status 6 D16A - D16B 0 to 1
Input Status 7 D16C - D16D 0 to 1
Input Status 8 D16E - D16F 0 to 1
7�3�4�5�- Status of transistor digital outputs
The following functions are implemented for these variables:
Function 0x04: reading registers.
Table 124:Modbus memory map: Status of transistor digital outputs (Table 1)�
Status of transistor digital outputs
Configuration variable Valid data window
Alarm
Impulse
output
Alarm
Impulse
output
Latch
(85)
kWh or Wh
0: unlock alarm
1: locked alarm
kWh or Wh energy meter
Delay in the connection
(86)
Wh or mWh
Energy meter which indicates
the value of the connection
delay variable (ON)
Wh or mWh energy meter
Delay in the disconnection
(86)
Energy
meter
factor
Energy meter which indicates
the value of the disconnection
delay variable (OFF)
Energy meter factor meter
Alarm activation date: Year
(86)
- 2013 to 2076 -
Alarm activation date: Month
(86)
- 1 to 12 -
Alarm activation date: Day
(86)
- 1 to 31 -
Alarm activation time: Hour
(86)
- 0 to 23 -
Alarm activation time: Minutes
(86)
- 0 to 59 -
Alarm activation time: Seconds
(86)
- 0 to 59 -
Not used - -
289
Instruction Manual
CVM-A1000 - CVM-A1500

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Circutor CVM-A1500 and is the answer not in the manual?

Circutor CVM-A1500 Specifications

General IconGeneral
BrandCircutor
ModelCVM-A1500
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals