EasyManua.ls Logo

Cisco 12000 - Chassis Alarms

Cisco 12000
602 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18-3
Cisco 12000/10700 v3.1.1 Router Manager User Guide
OL-4455-01
Chapter 18 Fault Management
Cisco 12000/10720 Router Trap Support
Informational
Normal
Chassis Alarms
Table 18-2 provides information on traps that result in alarms raised against the chassis object.
Table 18-2 Monitored Attributes for a GRP Module
Trap Alarm Description Severity Clears
Cold start Cold Start: Agent reinitializing; configuration
may have changed.
Major Cold start
RPR+ Switchover RPR+ Cold Start: Agent reinitializing;
configuration may have changed
Major RPR+ Switchover
RPR Switchover RPR Cold Start: Agent
reinitializing;configuration may have changed
Major RPR Switchover
Redundancy Framework (RF)
Progression
RF Notification: RF state has changed. Active
Unit: <slot-no> State: <RF-state>. Peer Unit:
<slot-no> State: <RF-state>
Major Redundancy
Framework (RF)
Progression
Warm start Warm Start: Agent reinitializing; configuration
is unaltered.
Major Warm start
Authentication Failure Authentication Failure Major Authentication
Failure
Voltage Normal Voltage higher Chassis, normal, <value> mV Normal Normal, Critical,
Shutdown, Warning,
NotPresent
Voltage Warning Voltage higher Chassis, warning, <value> mV Warning Critical, Shutdown,
Warning, NotPresent
Voltage Critical Voltage higher Chassis, critical, <value> mV Critical Critical, Shutdown,
Warning, NotPresent
Voltage Shutdown Voltage higher Chassis, shutdown, <value> mV Critical Critical, Shutdown,
Warning, NotPresent
Voltage Not Present Voltage higher Chassis, notPresent, <value> mV Informational Critical, Shutdown,
Warning, NotPresent
Temperature Normal Slot <no>: Switch Fabric Card Hot Sensor,
normal, <value> degree celsius
Normal Normal, Critical,
Shutdown, Warning,
NotPresent
Temperature Warning Slot <no>: Switch Fabric Card Hot Sensor,
warning, <value> degree celsius
Warning Critical, Shutdown,
Warning, NotPresent
Temperature Critical Slot <no>: Switch Fabric Card Hot Sensor,
critical, <value> degree celsius
Critical Critical, Shutdown,
Warning, NotPresent
Temperature Shutdown Slot <no>: Switch Fabric Card Hot Sensor,
shutdown, <value> degree celsius
Critical Critical, Shutdown,
Warning, NotPresent
Temperature Not Present Slot <no>: Switch Fabric Card Hot Sensor,
notPresent, <value> degree celsius
Informational Critical, Shutdown,
Warning, NotPresent

Table of Contents