15-23
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
78-11380-10
Chapter 15 Configuring MSTP
Displaying the MST Configuration and Status
Displaying the MST Configuration and Status
To display the spanning-tree status, use one or more of the privileged EXEC commands in Table 15-4:
For information about other keywords for the show spanning-tree privileged EXEC command, refer to
the command reference for this release.
Table 15-4 Commands for Displaying MST Status
Command Purpose
show spanning-tree mst configuration Displays the MST region configuration.
show spanning-tree mst instance-id Displays MST information for the specified instance.
show spanning-tree mst interface interface-id Displays MST information for the specified interface. Valid interfaces
include physical ports, VLANs, and port channels. Valid VLAN IDs are 1
to 1005 when the SI is installed and 1 to 4094 when the EI is installed. The
valid port-channel range is 1 to 6.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 2950 - Catalyst Switch and is the answer not in the manual?

Cisco 2950 - Catalyst Switch Specifications

General IconGeneral
Forwarding Rate6.6 Mpps
Jumbo Frame SupportNo
Weight8.8 lbs (4 kg)
RAM16 MB
Flash Memory8 MB
ManageableYes
Form FactorRack-mountable
Ports24 Ethernet 10/100 ports
Uplink Ports2 x 10/100/1000Base-T ports
VLANs250
MAC Address Table Size8000
Power Supply100-240 VAC, 50-60 Hz
Dimensions4.4 cm x 44.5 cm x 24.2 cm
Operating Temperature0 to 40 °C (32 to 104 °F)
Storage Temperature-25 to 70 °C (-13 to 158 °F)
Operating Humidity10% to 85% (non-condensing)
Storage Humidity5% to 95% (non-condensing)