18-15
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
78-11380-10
Chapter 18 Configuring VTP
Configuring VTP
Beginning in privileged EXEC mode, follow these steps to verify and reset the VTP configuration
revision number on a switch before adding it to a VTP domain:
You can also change the VTP domain name by entering the vlan database privileged EXEC command
to enter VLAN configuration mode and by entering the vtp domain domain-name command. In this
mode, you must enter the exit command to update VLAN information and return to privileged EXEC
mode.
After resetting the configuration revision number, add the switch to the VTP domain.
Note You can use the vtp mode transparent global configuration command or the vtp transparent VLAN
configuration command to disable VTP on the switch, and then change its VLAN information without
affecting the other switches in the VTP domain.
Command Purpose
Step 1
show vtp status Check the VTP configuration revision number.
If the number is 0, add the switch to the VTP domain.
If the number is greater than 0, follow these steps:
a. Write down the domain name.
b. Write down the configuration revision number.
c. Continue with the next steps to reset the configuration revision number on the
switch.
Step 2
configure terminal Enter global configuration mode.
Step 3
vtp domain domain-name Change the domain name from the original one displayed in Step 1 to a new name.
Step 4
end The VLAN information on the switch is updated and the configuration revision
number is reset to 0. You return to privileged EXEC mode.
Step 5
show vtp status Verify that the configuration revision number has been reset to 0.
Step 6
configure terminal Enter global configuration mode.
Step 7
vtp domain domain-name Enter the original domain name on the switch.
Step 8
end The VLAN information on the switch is updated, and you return to privileged EXEC
mode.
Step 9
show vtp status (Optional) Verify that the domain name is the same as in Step 1 and that the
configuration revision number is 0.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 2950 - Catalyst Switch and is the answer not in the manual?

Cisco 2950 - Catalyst Switch Specifications

General IconGeneral
Forwarding Rate6.6 Mpps
Jumbo Frame SupportNo
Weight8.8 lbs (4 kg)
RAM16 MB
Flash Memory8 MB
ManageableYes
Form FactorRack-mountable
Ports24 Ethernet 10/100 ports
Uplink Ports2 x 10/100/1000Base-T ports
VLANs250
MAC Address Table Size8000
Power Supply100-240 VAC, 50-60 Hz
Dimensions4.4 cm x 44.5 cm x 24.2 cm
Operating Temperature0 to 40 °C (32 to 104 °F)
Storage Temperature-25 to 70 °C (-13 to 158 °F)
Operating Humidity10% to 85% (non-condensing)
Storage Humidity5% to 95% (non-condensing)