EasyManuals Logo

Cisco 8961 Administration Guide

Cisco 8961
378 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #243 background imageLoading...
Page #243 background image
DescriptionField
Length of time that the display remains on after turning on at the time that the
Display On Time field specifies.
Enter the value in this field in the format hours:minutes.
For example, to keep the display on for 4 hours and 30 minutes after it turns on
automatically, enter 4:30.
If this field is blank, the phone turns off at the end of the day (0:00).
If Display On Time is 0:00 and the display on duration is blank (or
24:00), the display remains on continuously.
Note
The default value is 10:30.
Display On Duration
Length of time that the phone remains idle before the display turns off. Applies
only when the display was powered off as scheduled and was turned on by a
user (by pressing Select on the phone).
Enter the value in this field in the format hours:minutes.
For example, to turn the display off when the phone is idle for 1 hour and 30
minutes after a user turns the display on, enter 1:30.
The default value is 1:00.
Display Idle Timeout
EnergyWise on the Cisco Unified IP Phone Setup
To reduce power consumption, configure the phone to sleep (power down) and wake (power up) if your system
includes an EnergyWise controller.
You configure settings in Cisco Unified Communications Manager Administration to enable EnergyWise and
configure sleep and wake times. These parameters are closely tied to the phone display configuration parameters.
When EnergyWise is enabled and a sleep time is set, the phone sends a request to the switch to wake it up at
the configured time. The switch returns either an acceptance or a rejection of the request. If the switch rejects
the request or if the switch does not reply, the phone does not power down. If the switch accepts the request,
the idle phone goes to sleep, thus reducing the power consumption to a predetermined level. A phone that is
not idle sets an idle timer and goes to sleep after the timer expires.
To wake up the phone press Select. At the scheduled wake time, the system restores power to the phone,
waking it up.
The following table explains the Cisco Unified Communications Manager Administration fields that control
the EnergyWise settings. You configure these fields in Cisco Unified Communications Manager Administration
in the Product Specific Configuration area of the Phone Configuration window Device > Phone.
Cisco Unified IP Phone 8961, 9951, and 9971 Administration Guide for Cisco Unified Communications Manager 10.0
(SIP)
219
Cisco Unified IP Phone Customization
EnergyWise on the Cisco Unified IP Phone Setup
REVIEW DRAFT - CISCO CONFIDENTIAL

Table of Contents

Other manuals for Cisco 8961

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 8961 and is the answer not in the manual?

Cisco 8961 Specifications

General IconGeneral
Resolution640 x 480 pixels
Display5-inch TFT color display
Ethernet10/100/1000 Mbps
PowerIEEE 802.3af Power over Ethernet (PoE) Class 3
ConnectivityTwo-port Gigabit Ethernet switch
Buttons4 softkeys
USB PortYes, supports USB 2.0
Headset JackYes, dedicated headset port
SpeakerphoneFull-duplex speakerphone
Codec SupportG.711, G.722, G.729, iLBC
Security802.1X authentication, TLS, SRTP, HTTPS