Loading...
14-68
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 14 Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Removing and Replacing the Cisco ASR 1004 Router Power Supplies
Note The ground wire must contain a loop when securing it to the tie-wrap tab to prevent it from being
pulled out.
Step 11 Replace the terminal block plastic cover, which is slotted and keyed to fit correctly over the terminal
block; then tighten the black screw (use the screwdriver to tighten the screw to a torque of 5 in-lbs / 1
per.). See Figure 14-48.
Figure 14-48 Cisco ASR 1006 Router DC Power Supply Terminal Block Plastic Cover and Switch
Step 12 Remove the tape from the circuit-breaker On/Off switch.
Step 13 Switch the circuit breaker On/Off switch to the On (|) position.
Note The requirement for maximum torque applied to the power or ground Kepnuts must be 8 in-lb when the
power or ground lug is not present.
This completes the procedure for installing the DC power supply into the Cisco ASR 1006 Router.
Removing and Replacing the Cisco ASR 1004 Router Power
Supplies
The Cisco ASR 1004 Router contains power supplies that are field replaceable units. This section
contains the following topics:
Removing and Replacing an AC Power Supply in Cisco ASR 1004 Router, page 14-69
1 DC power supply On/Off switch 2 Terminal block plastic cover black screw
OFF
55
-48/-60V 40A
280026
1
2