Chapter 4 Troubleshooting
Diagnosing Problems
4-6
Catalyst 3750 Switch Hardware Installation Guide
78-15136-03
No connectivity Incorrect or bad cable
These are results of no link at both
ends:
A crossover cable was used
when a straight-through was
required, or vice-versa.
The cable is wired incorrectly.
A crossover or straight-through
cable is wired incorrectly.
STP checking for possible
loops.
For the correct pinouts and
the proper application of
crossover vs.
straight-through cables, see
the Two Twisted-Pair
Cable Pinouts section on
page B-5.
Enable the automatic
medium-dependent-
interface crossover
(Auto-MDIX) feature.
Note Many legacy powered
devices, including older
Cisco IP phones and
access points that do not
fully support IEEE
802.3af, might not
support PoE when
connected to the
switches by a crossover
cable.
Replace with a tested good
cable.
For 1000BASE-T
connections, be sure to use
a twisted four-pair,
Category 5 cable.
Wait 30 seconds for the port
LED to turn green.
Table 4-1 Common Problems and Solutions (continued)
Symptom Possible Cause Resolution

Table of Contents

Other manuals for Cisco Catalyst 3750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 3750 and is the answer not in the manual?

Cisco Catalyst 3750 Specifications

General IconGeneral
Device TypeSwitch
Switching Capacity32 Gbps
Forwarding Rate38.7 Mpps
Stacking Bandwidth32 Gbps
RAM128 MB
Jumbo Frame SupportYes
Switch TypeManaged
ModelCatalyst 3750 Series
Uplink InterfacesSFP
Form FactorRack-mountable
MAC Address Table Size12, 000 entries
Routing ProtocolRIP, OSPF, EIGRP
Remote Management ProtocolSNMP, Telnet, HTTP
FeaturesLayer 3 switching, Layer 2 switching, auto-negotiation, BOOTP support, ARP support, VLAN support, auto-uplink (auto MDI/MDI-X), IGMP snooping, traffic shaping, MAC address filtering, Quality of Service (QoS), Jumbo Frames support, MLD snooping, Dynamic ARP Inspection (DAI), Cisco EnergyWise technology
Power over Ethernet (PoE)PoE
Operating Temperature-5 - 45 °C
Operating Humidity10% to 85% non-condensing