2-116
Catalyst 4500 Series Switch Cisco IOS System Message Guide Release 12.2(31)SGA
OL-11541-01
Chapter 2 Messages and Recovery Procedures
SWITCHMANAGER Messages
Error Message C4K_SWITCHMANAGER-3-SSOHARDWAREACKTIMEOUT: Internal Event: timed out
after [dec] iterations waiting for the [char] hardware to be programmed
Explanation
The active supervisor engine is taking more time than usual to program the hardware.
This should not affect normal behavior or SSO functionality. In the worst case you may see link flaps
when the supervisor engines switch over.
Recommended Action This is an informational message only. No action is required. If the problem
persists, contact your technical support representative.
SWITCHMANAGER-4
Error Message C4K_SWITCHMANAGER-4-CANTPOWEROFF:Internal Error: PimEthAutoNegotiator
- Can't power off port [char]
Explanation
This is an internal software error in an inline-power state machine.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_SWITCHMANAGER-4-CANTPOWERON:Internal Error: PimEthAutoNegotiator
- Can't power on port [char]
Explanation This is an internal software error in an inline-power state machine.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_SWITCHMANAGER-4-HARDWAREERROR:Power management hardware for port
[char] bad.
Explanation
The switch cannot change the inline-power state for this port.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_SWITCHMANAGER-4-S2WERROR:Power control to port [char] bad.
Possibly power is turned on.
Explanation
This is a communication error in PoE power management.