2-40
Catalyst 4500 Series Switch Cisco IOS System Message Guide Release 12.2(31)SGA
OL-11541-01
Chapter 2 Messages and Recovery Procedures
IDBMAN Messages
HWPORTMAN-7
Error Message C4K_HWPORTMAN-7-FLOWCONTROLPACKET:Received invalid flow control
packet from [char] da [mac-addr] sa [mac-addr] ethertype [hex] opcode [hex]
Explanation
The supervisor engine forwarded a malformed flow control packet to the software
because one or both of the EtherType and flow control/operation code is incorrect. For flow control
packets, the expected EtherType is 0x8808, and the expected operation code is 1 (xoff).
Recommended Action If the devices that are connected to the switch can generate flow control and
are configured for flow control, verify that the devices can generate well-formed flow control
packets with valid EtherType and operation code fields.
IDBMAN Messages
This section contains the interface descriptor block (IDB) management (IDBMAN) messages.
IDBMAN-3
Error Message IDBMAN-3-AGGPORTMISMATCH:[char]:[char]([dec] / [dec]) does match
internal slot/port state [char]([dec] / [dec])
Explanation Due to an internal error the software is using an invalid aggregate port.
Recommended Action This is an informational message only. No action is required.
Error Message IDBMAN-3-DELETEDAGGPORT:[char]([dec] / [dec]) Group [dec] has been
deleted
Explanation
Software is reusing a deleted interface for a new aggregate port.
Recommended Action This is an informational message only. No action is required.
Error Message IDBMAN-3-INVALIDAGGPORTBANDWIDTH:[char]([dec] / [dec]) has an invalid
bandwidth value of [dec]
Explanation
Software is using an invalid bandwidth for an aggregate port.
Recommended Action This is an informational message only. No action is required.
Error Message IDBMAN-3-INVALIDPORT:[char]:trying to use invalid port number [dec]
(Max [dec])
Explanation
Software is using an invalid port number.
Recommended Action This is an informational message only. No action is required.

Table of Contents

Other manuals for Cisco Catalyst 4500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 4500 Series and is the answer not in the manual?

Cisco Catalyst 4500 Series Specifications

General IconGeneral
SeriesCatalyst 4500 Series
CategorySwitch
Layer SupportLayer 2, Layer 3
Form FactorModular chassis
StackableNo
Chassis Slots3, 6, 7, 10
Power Supply OptionsAC, DC
RedundancyPower supply, Supervisor engine
Network ManagementCisco IOS Software CLI, SNMP, Cisco Prime Infrastructure
FeaturesSecurity, QoS
Port DensityUp to 384 ports per chassis
Security Features802.1X, ACLs, DHCP Snooping, Dynamic ARP Inspection, IP Source Guard
Supervisor Engine8-E

Related product manuals