2-54
Catalyst 4500 Series Switch Cisco IOS System Message Guide Release 12.2(31)SGA
OL-11541-01
Chapter 2 Messages and Recovery Procedures
IOSMODPORTMAN Messages
Error Message C4K_IOSMODPORTMAN-4-TEMPHIGH: Chassis temperature is at or over
threshold - CurrentTemp: [dec]C, Threshold: [dec]C
Explanation
The chassis temperature is above the threshold. If the temperature goes above a critical
threshold, another message is logged and the system shuts down to prevent damage to the hardware.
Recommended Action Inspect the chassis and environment to determine the cause of the rise in
temperature. Cool the system.
Error Message C4K_IOSMODPORTMAN-4-TEMPUNDERCRITICAL: Chassis temperature is now
under critical threshold but still very high - current temp: [object-info] C,
critical threshold: [object-info] C
Explanation
The chassis temperature is now below the critical threshold. The chassis is still
operating above the normal temperature.
Recommended Action Inspect the chassis to determine the cause of the temperature problem. Cool the
system.
IOSMODPORTMAN-6
Error Message C4K_IOSMODPORTMAN-6-CLOCKSWITCHOVER: Chassis Clock Module switched to
Clock: [dec]
Explanation
This indicates that the clock module switched over to another clock.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-INLINEPOWERSUPPLYGOOD: Inline power from power
supply [dec] is Ok
Explanation The PoE power supply just inserted in [dec] is functioning normally.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-POWERSUPPLYOUTPUTINCREASED: Power supply [dec]
output has increased
Explanation
The indicated power supply output increased.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-FANTRAYINSERTED:Fan tray has been inserted
Explanation
The fan tray was inserted.
Recommended Action This is an informational message only. No action is required.