Page #75 background image
2-55
Catalyst 4500 Series Switch Cisco IOS System Message Guide Release 12.2(31)SGA
OL-11541-01
Chapter 2 Messages and Recovery Procedures
IOSMODPORTMAN Messages
Error Message C4K_IOSMODPORTMAN-6-FANTRAYINSERTEDDETAILED: Fan tray ([char] S/N:
[char] Hw: [dec].[dec]) has been inserted
Explanation
The fan tray was inserted.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-INLINEPOWEROK:Inline power within limits:Module
status changed to 'Ok'
Explanation
The measured PoE is now below the configured value and the physical limit for the
module.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-MODULEINSERTED: Module [dec] is inserted
Explanation A module was inserted into slot [dec].
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-MODULEOFFLINE: Module [dec] is offline
Explanation
The specified module is offline.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-MODULEONLINE:Module [dec] ([char] S/N:[char]
Hw:[dec].[dec]) is online
Explanation
The specified module is online.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-MODULEREMOVED: Module [dec] is removed
Explanation
A module was removed from slot [dec].
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-PACKETMEMORYERRORPOWERCYCLE:Supervisor power
cycled due to packet memory errors
Explanation
This supervisor engine was power cycled to get rid of SRAM errors detected in the
packet memory. It is expected that the transient SRAM errors in packet memory are cleared by a
power cycle of a supervisor engine.
Recommended Action Contact your technical support representative.

Table of Contents

Other manuals for Cisco Catalyst 4500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 4500 Series and is the answer not in the manual?

Cisco Catalyst 4500 Series Specifications

General IconGeneral
SeriesCatalyst 4500 Series
CategorySwitch
Layer SupportLayer 2, Layer 3
Form FactorModular chassis
StackableNo
Chassis Slots3, 6, 7, 10
Power Supply OptionsAC, DC
RedundancyPower supply, Supervisor engine
Network ManagementCisco IOS Software CLI, SNMP, Cisco Prime Infrastructure
FeaturesSecurity, QoS
Port DensityUp to 384 ports per chassis
Security Features802.1X, ACLs, DHCP Snooping, Dynamic ARP Inspection, IP Source Guard
Supervisor Engine8-E

Related product manuals