Error Message C4K_IOSMODPORTMAN-6-FANTRAYINSERTEDDETAILED: Fan tray ([char] S/N:
[char] Hw: [dec].[dec]) has been inserted
Explanation
The fan tray was inserted.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-INLINEPOWEROK:Inline power within limits:Module
status changed to 'Ok'
Explanation
The measured PoE is now below the configured value and the physical limit for the
module.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-MODULEINSERTED: Module [dec] is inserted
Explanation A module was inserted into slot [dec].
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-MODULEOFFLINE: Module [dec] is offline
Explanation
The specified module is offline.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-MODULEONLINE:Module [dec] ([char] S/N:[char]
Hw:[dec].[dec]) is online
Explanation
The specified module is online.
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-MODULEREMOVED: Module [dec] is removed
Explanation
A module was removed from slot [dec].
Recommended Action This is an informational message only. No action is required.
Error Message C4K_IOSMODPORTMAN-6-PACKETMEMORYERRORPOWERCYCLE:Supervisor power
cycled due to packet memory errors
Explanation
This supervisor engine was power cycled to get rid of SRAM errors detected in the
packet memory. It is expected that the transient SRAM errors in packet memory are cleared by a
power cycle of a supervisor engine.
Recommended Action Contact your technical support representative.