Chapter 2 Messages and Recovery Procedures
PM Messages
Error Message PM-4-PORT_INCONSISTENT: Port [char] is inconsistent: IDB state [char]
(set %TE ago)
Explanation
The port manager on the standby supervisor engine discovered that the port state was
inconsistent for more that one second. Inconsistent ports are reactivated on switchover (you will see
the PORT_BOUNCED message).
Recommended Action This is an informational message only. No action is required.
Error Message PM-4-PVLAN_TYPE_CFG_ERR: Failed to set VLAN [dec] to a [char] VLAN
Explanation
The platform failed to set the private VLAN type.
Recommended Action Enter the show tech-support privileged EXEC command to gather data that
might provide information about the error. If you cannot determine the cause of the error from the
error message or from the show tech-support command display, copy the error message exactly as
it appears on the console or in the system log, contact your technical support representative, and
provide the representative with the gathered information.
Error Message PM-4-TOO_MANY_APP:application ā[char]ā exceeded registration limit
Explanation
The Port Manager detected an invalid request. [char] in the application.
Recommended Action Reconfigure the host access entry using the correct type.
Error Message PM-4-UNKNOWN_HOST_ACCESS: Invalid Host access value ([dec]) is
received
Explanation
A n invalid host access value was sent to the host access table.
Recommended Action Reconfigure the host access entry using the correct type.
Error Message PM-4-VMPS_CFG: Dynamic access VLAN [dec] same as voice vlan on [char].
Explanation
The access VLAN on the VMPS server is set to the same VLAN as the voice VLAN on
the port.
Recommended Action Change the assignments so that the access VLAN assignment on the VMPS
server is different from the voice VLAN.