controller BITS shutdown
controller BITS shutdown
To shut down the Building Integrated Timing Supply (BITS) clock controller, use the controller BITS
shutdown command in global configuration mode.To reverse the shutdown, use the no form of this
command.
controller BITS shutdown
no controller BITS shutdown
Syntax Description This command has no keywords.
Defaults The clock controller is on by default.
Command Modes Global configuration
Command History
Examples This example shows how to shut down the BITS controller:
Switch(config)# controller BITS shutdown
Switch(config)# exit
Related Commands
Release Modification
12.2(52)EY This command was introduced.