Send feedback to nx5000-docfeedback@cisco.com
1-5
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Configuring Domain Parameters
Information About Fibre Channel Domains
Configuring Switch Priority
To configure the priority for the principal switch, perform this task:
About fcdomain Initiation
By default, the fcdomain feature is enabled on each switch. If you disable the fcdomain feature in a
switch, that switch can no longer participate with other switches in the fabric. The fcdomain
configuration is applied to runtime through a disruptive restart.
Disabling or Reenabling fcdomains
To disable or reenable fcdomains in a single VSAN or a range of VSANs, perform this task:
Configuring Fabric Names
To set the fabric name value for a disabled fcdomain, perform this task:
About Incoming RCFs
You can configure the rcf-reject option on a per-interface, per-VSAN basis. By default, the rcf-reject
option is disabled (that is, RCF request frames are not automatically rejected).
Command Purpose
Step 1
switch# configuration terminal
switch(config)#
Enters configuration mode.
Step 2
switch(config)# fcdomain priority number VSAN
vsan-id
Configures the specified priority for the local
switch in the specified VSAN.
switch(config)# no fcdomain priority number
VSAN vsan-id
Reverts the priority to the factory default (128)
in the specified VSAN.
Command Purpose
Step 1
switch# configuration terminal
switch(config)#
Enters configuration mode.
Step 2
switch(config)# no fcdomain vsan
vsan-id - vsan-id
Disables the fcdomain configuration in the specified
VSAN range.
switch(config)# fcdomain vsan vsan-id
Enables the fcdomain configuration in the specified
VSAN.
Command Purpose
Step 1
switch# configuration terminal
switch(config)#
Enters configuration mode.
Step 2
switch(config)# fcdomain fabric-name
20:1:ac:16:5e:0:21:01 vsan vsan-id
Assigns the configured fabric name value in the
specified VSAN.
switch(config)# no fcdomain fabric-name
20:1:ac:16:5e:0:21:01 vsan vsan-id
Changes the fabric name value to the factory default
(20:01:00:05:30:00:28:df) in VSAN 3010.