EasyManua.ls Logo

Cisco Nexus 5000 Series - Verifying Fcdomain Information

Cisco Nexus 5000 Series
660 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Send feedback to nx5000-docfeedback@cisco.com
1-19
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Configuring Domain Parameters
Verifying fcdomain Information
Verifying fcdomain Information
Note If the fcdomain feature is disabled, the runtime fabric name in the display is the same as the configured
fabric name.
This example shows how to display information about fcdomain configurations:
switch# show fcdomain vsan 2
Use the show fcdomain domain-list command to display the list of domain IDs of all switches
belonging to a specified VSAN. This list provides the WWN of the switches owning each domain ID.
The next example uses the following values:
A switch with WWN of 20:01:00:05:30:00:47:df is the principal switch and has domain 200.
A switch with WWN of 20:01:00:0d:ec:08:60:c1 is the local switch (the one where you typed the
CLI command to show the domain-list) and has domain 99.
The IVR manager obtained virtual domain 97 using 20:01:00:05:30:00:47:df as the WWN for a
virtual switch.
switch# show fcdomain domain-list vsan 76
Number of domains: 3
Domain ID WWN
--------- -----------------------
0xc8(200) 20:01:00:05:30:00:47:df [Principal]
0x63(99) 20:01:00:0d:ec:08:60:c1 [Local]
0x61(97) 50:00:53:0f:ff:f0:10:06 [Virtual (IVR)]
Use the show fcdomain allowed vsan command to display the list of allowed domain IDs configured
on this switch..
switch# show fcdomain allowed vsan 1
Assigned or unallowed domain IDs: 1-96,100,111-239.
[Interoperability Mode 1] allowed domain IDs: 97-127.
[User] configured allowed domain IDs: 50-110.
Tip Ensure that the requested domain ID passes the switch software checks, if interop 1 mode is required in
this switch.
The following example shows how to display all existing, persistent FC IDs for a specified VSAN. You
can also specify the unused option to view only persistent FC IDs that are still not in use.
switch# show fcdomain fcid persistent vsan 1000
The following example shows how to display frame and other fcdomain statistics for a specified VSAN
or SAN port channel:
switch# show fcdomain statistics vsan 1
VSAN Statistics
Number of Principal Switch Selections: 5
Number of times Local Switch was Principal: 0
Number of 'Build Fabric's: 3
Number of 'Fabric Reconfigurations': 0