Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Configuring and Managing Zones
Information About Zoning
Figure 1-2 Fabric with Three Zones
Zone Implementation
Cisco Nexus 5000 Series switches automatically support the following basic zone features (no additional
configuration is required):
Zones are contained in a VSAN.
Hard zoning cannot be disabled.
Name server queries are soft-zoned.
Only active zone sets are distributed.
Unzoned devices cannot access each other.
A zone or zone set with the same name can exist in each VSAN.
Each VSAN has a full database and an active database.
Active zone sets cannot be changed, without activating a full zone database.
Active zone sets are preserved across switch reboots.
Changes to the full database must be explicitly saved.
Zone reactivation (a zone set is active and you activate another zone set) does not disrupt existing
traffic.
If required, you can additionally configure the following zone features:
Propagate full zone sets to all switches on a per VSAN basis.
Change the default policy for unzoned members.
Interoperate with other vendors by configuring a VSAN in the interop mode. You can also configure
one VSAN in the interop mode and another VSAN in the basic mode in the same switch without
disrupting each other.
Bring E ports out of isolation.
H1 S1
S2
S3
H2
H3
Zone 1
Zone 2
Zone 3
79536