EasyManua.ls Logo

Cisco Nexus 5000 Series - Page 94

Cisco Nexus 5000 Series
660 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Send feedback to nx5000-docfeedback@cisco.com
1-10
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Configuring Ethernet Interfaces
Displaying Interface Information
0 babble
0 Rx pause 8031547972 Tx pause 0 reset
The following example shows how to display the physical Ethernet capabilities:
switch# show interface ethernet 1/3 capabilities
Ethernet1/1
Model: AGD11342302
Type: 10Gbase-SR
Speed: 1000,10000
Duplex: full
Trunk encap. type: 802.1Q
Channel: no
Broadcast suppression: percentage(0-100)
Flowcontrol: rx-(off/on),tx-(off/on)
Rate mode: none
QOS scheduling: rx-(6q1t),tx-(1p6q0t)
CoS rewrite: no
ToS rewrite: no
SPAN: yes
UDLD: yes
Link Debounce: yes
Link Debounce Time: yes
MDIX: no
The following example shows how to display the physical Ethernet transceiver:
switch# show interface ethernet 1/3 transceiver
Ethernet1/3
sfp is present
name is CISCO-AVAGO
part number is SFBR-7700SDZ B4 R
revision is B4 R
serial number is AGD1134229V 070823
nominal bitrate is 0 MBits/sec
Link length supported for 50/125mm fiber is 0 m(s)
Link length supported for 62.5/125mm fiber is 0 m(s)
cisco id is --
cisco extended id number is 4
The following example shows how to display a brief interface status (some of the output has been
removed for brevity):
switch# show interface brief
--------------------------------------------------------------------------------
Ethernet VLAN Type Mode Status Reason Speed Port
Interface Ch #
--------------------------------------------------------------------------------
Eth1/1 200 eth trunk up none 10G(D) --
Eth1/2 1 eth trunk up none 10G(D) --
Eth1/3 300 eth access down SFP not inserted 10G(D) --
Eth1/4 300 eth access down SFP not inserted 10G(D) --
Eth1/5 300 eth access down Link not connected 1000(D) --
Eth1/6 20 eth access down Link not connected 10G(D) --
Eth1/7 300 eth access down SFP not inserted 10G(D) --
...
The following example shows how to display the link debounce status (some of the output has been
removed for brevity):
switch# show interface debounce
--------------------------------------------------------------------------------

Table of Contents