UNITY INSTALLATION GUIDE
158
Natural
MicroSystems AG
Continued
Dual T1 voice board
Hardware settings
None.
Software settings
During Unity Setup, do the following procedure when the NMS
Configurator dialog box appears.
To enter AG Dual T1 settings during Unity setup
a Select a country.
b Select the first board in the list.
c Click “Configure board.” The Configure Board dialog box
appears.
d In the Board Type list, confirm that the value is “AG Dual
T1.”
e In the TAPI Lines list, confirm that the value is “48.”
f The value you specify in the Protocol list depends on the
type of phone system you are connecting the Unity server to.
g On the Windows NT Start menu, click Programs >
Command Prompt.
Or on the Windows 2000 Start menu, click Programs >
Accessories > Command Prompt.
h At the command prompt, type
\<directory that contains NMS files>\bin\blocate
and press ENTER. Values for bus, slot, and interrupt
appear.
i Make note of the values for bus and for slot.
j Type
Exit and press ENTER to close the command prompt
window.
k Verify the values for bus and slot.
Phone system Protocol list value
Mitel SX-2000 Digital/Analog Wink-Start
NEC NEAX 2400 Digital Loop-Start (OPS-FX)