Chapter 3. Installation
91
Table 3-12. Maximum Data Line Cards Power Matrix for 24-Slot Shelf
Line Cards
110 V
Smart AC
Power
Supply
30308-102
AC/DC
Power
Supplies
30315-105 &
30338-103
-48 V
Redundant DC
Power Supply
30338-102
1 Unit or
2 Redundant
-48 V
Redundant
DC Power
Supply
30338-102
2 Non-
Redundant
-24 V
Redundant
DC Power
Supply
30314-101
1 Unit or
2 Redundant
SDCU with V.35
Interface, 30251-,
30252- and 30351-
XX1 or XX3
8
18
24
24
24
SDCU with RS-422
Interface, 30251-,
30252-, and 30351-
XX1 or XX3
24
18
24
24
24
DSDCU with V.35
Interface, 30451-
101
8 8 24 24 24
DSDCU with
RS-422 Interface,
30451-101
24 18 24 24 24
DSDCU with
RS-232C Interface,
30451-101
18 18 18 24 18
SDM, pSDM 30355-
XXX
12 (24
Opt*)
10 (20 Opt**) 12 (24 Opt*) 24 12 (24 Opt*)
OCUDP 30358-
106/107/108
24 24 24 24 24
Async DCU 30011-
1XX
24 18 24 24 24
Async DCU 30011-
0XX
8 16 24 24 24
DSUDP 30358-101 8 18 24 24 24
Full configuration for the SDM product is defined as operating with five fully utilized subrate channels per
DS0 with all five RS-232C drivers active per subrate channel. This totals 25 RS-232C drivers active on
an SDM line card. If an application is such that half as many (or less) RS-232C drivers are needed, then
twice the number of SDM line cards can be powered, as shown in the parentheses as an "Optional"
amount.