Chapter 4. Configuration and Operation
151
] SP
Enter System Operation Parameters
Use Installed Line Cards to Cross-check Map Display/Edit
Y) Yes
N) No
[Y] Y
Shelf Size
8)
12)
24)
[24]
System ID
[0]
System Label
[ ]
Set System Date and Time
Y) Yes
N) No
[N]
Set T1 Alarm Processing
Y) Yes
N) No
[N]
Jitter Attenuator
1) Enable
2) Disable
Enter [2] for disable, unless known jitter is present.
Jitter Attenuator Depth
1) 28 UI
2) 120 UI
[1]
REM Alarm
1) Pass Thru
2) Block
[2]
Apply Changes
Y) Yes
N) No
[Y/N] N
]
Figure 4-60. Setting System Operation Parameters