D/I Mux III User’s Manual Appendix I. Traps and Modem Dial Out Configuration
291
The path for this system is: D/I Mux III with an AMCU, to an external modem (using a cable with an
RJ-45 connector on the AMCU end and a DB-9 connector on the modem end) to a phone line to the
Network, from the network to a modem to the SNMP manager Mux. .
MODEM DIAL OUT
MD
Modify Dial Out Parameters
If the AMCU is appropriately configured, a trap can cause the AMCU to dial out on a customer
supplied modem to reach an SMNP manager. This command allows the user, via menu selections
to do the following:
• Configure the SLIP port of the AMCU for modem or no modem
• Set the length of inactivity (Timeout) before the modem hangs up.
• Input a Modem Initialization String.
• Add, Change the ordered list, or Delete dial out numbers.
• View the configuration of the site with the new parameters
• Apply the changes