D/I Mux III User’s Manual Appendix I. Traps and Modem Dial Out Configuration
293
SET TIMEOUT
Selecting menu option “T” the user sets the number of inactive minutes allowed before the modem
hangs up. Minimum is approximately 15-20 seconds but is rounded to zero minutes. Sending or
receiving a SLIP packet restarts the timer.
Modify Dial Out Parameters
-------------------------------
M Modem present?
T Timeout
I Modem initialization string
N Dail out numbers
V View dial out parameters
Q Quit
Select parameter to set or modify [Q] T
Modem Inactivity Timeout: 1 Min.
0. Minimum
1. 1 Minute
2. 5 Minutes
3. 10 Minutes
4. 30 Minutes
Q. Quit
[Q]
Figure J-6 Set Timeout