USER MANUAL FOR mPICO SERIES
ENU Status : 1-0-1
Copyright - refer to title page
Page 43
Table 9: OMC Config.
Item
Description
Alarm Report Phone
No.
The Report No. is the SIM card number of the modem built into the OMC
Server computer. The equipment will send alarm to this number.
If remote communication is needed via modem, users have to enable SMS
mode and set the report phone No. by entering the SIM card number of the
equipment built-in modem.
Communication Mode
Communication mode includes SMS and Packet Switched Domain
OMC Server IP Port
Input the port number of OMC IP address.
OMC Server IP
Input the OMC IP address.
SMSC No.
It specifies the SMS center. Users have to set the service No. of SMSC for the
first installation, so that the alarms can be sent to OMC.
Equipment Data
Receive Port
The equipment’s own communication port can be set in a certain range which
users can see in the remark.
Remote
Communication Mode
Choose the modem type for monitoring, normally is WCDMA MODEM.
Heartbeat Detect
Interval
Equipment and OMC communication interval can be set anytime by user
according to real application.
PSD Access Point
Input the APN of local operator’s GPRS network. E.g., .uninet is for China
Unicom.
PSD Logon Password
/ User Name
Input the logon password and user name of APN.
PSD Parameter
Equipment IP Add
Input the IP address to realize connection of equipment and Internet.
PSD Transmission
Protocol
Choose the [IP+TCP]
Alarm Notice Phone
No Enable
Enable or disable the alarm notice phone number.
Alarm Notice Phone
No
Input the phone number by which you can receive the alarm notice .You can
input totally 3 alarm notice phone number.
Phone No. Checking
Select “Enable” or “Disable” to enable or disable the Phone Number
Authentication feature. Refer to [Phone No.] in details.
Query/Config Phone
No.
This is designed for authentication purpose when remote connection via
modem is required. It is the phone number to dial the equipment. Only the
phone number pre-defined in this field, will it be allowed to dial the equipment.
It is required to manually enter the phone number. Up to 5 phone numbers are
allowed. The use of phone number authentication can avoid unauthorized use
of the OMT. In addition, it can prevent the equipment receiving piles of spam
short messages, thus help the operator greatly reduce the cost.