Diagnostics and Troubleshooting 3-15
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of Problem Recommended Action
1731 - Fixed Disk 1
does not support
DMA Mode.
None Hard drive error Run the System Configuration
Utility and correct.
1740 - Fixed Disk 0
failed Set Block
Mode command
None Hard drive error Run the System Configuration
Utility and correct.
1741 - Fixed Disk 1
failed Set Block
Mode command
None Hard drive error Run the System Configuration
Utility and correct.
1750 - Fixed Disk 0
failed Identify
command
None Hard drive error Run the System Configuration
Utility and correct.
1751 - Fixed Disk 1
failed Identify
command
None Hard drive error Run the System Configuration
Utility and correct.
1760 - Fixed Disk 0
does not support
Block Mode
None Hard drive error Run the System Configuration
Utility and correct.
1761 - Fixed Disk 1
does not support
Block Mode
None Hard drive error Run the System Configuration
Utility and correct.
1764 - Slot x Drive Array Capacity Expansion Process is temporarily disabled
(followed by one of the following):
Expansion will resume when Array Accelerator has been reattached.
Expansion will resume when Array Accelerator has been replaced.
Expansion will resume when Array Accelerator RAM allocation is successful.
Expansion will resume when Array Accelerator battery reaches full charge.
Expansion will resume when automatic data recovery has been completed.
Reattach or replace Array
Accelerator, wait until the Array
Accelerator batteries have
charged, or for automatic data
recovery to complete, as
indicated.
*1766 - Slot x Drive Array requires System ROM Upgrade. Run Systems ROMPaq
Utility.
Run the latest Systems ROMPaq
Utility to upgrade the system
ROMs. Press F1 to resume.
1767 - Slot x Drive Array Option ROM is Not Programmed Correctly or may Conflict
with the Memory Address Range of an Option Card. Check the Memory Address
Configuration of installed Option Card(s) or run Options ROMPaq Utility to attempt
SMART-2/E Option ROM Reprogramming.
Remove or reconfigure
conflicting Option cards,
especially any cards that are not
recognized by the System
Configuration Utility. Try
reprogramming the ROM on the
SMART-2/E Controller using the
latest Options ROMPaq
(version 2.29 or higher).
continued

Table of Contents

Other manuals for Compaq PROLIANT ML370

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq PROLIANT ML370 and is the answer not in the manual?

Compaq PROLIANT ML370 Specifications

General IconGeneral
BrandCompaq
ModelPROLIANT ML370
CategoryServer
LanguageEnglish

Related product manuals