3-8 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code Audible Beeps Probable Source of Problem Recommended Action
A Critical Error
occurred prior to this
power-up
None A catastrophic system error,
which caused the server to
crash, has been logged.
Run Diagnostics. Replace failed
assembly as indicated.
Unsupported
Processor Detected
System Halted
1 long, 1 short Processor not supported by
current system ROM
Check documentation for
supported processors, and if
supported, remove the
processor and update the
system to latest ROM.
FATAL ROM ERROR:
The System ROM is
not properly
programmed
1 long, 1 short ROM programmed in factory
incorrectly
Replace the physical ROM part.
101 - ROM Error 1 long, 1 short System ROM checksum Run Diagnostics. Replace failed
assembly as indicated.
101 - I/O ROM Error None Options ROM checksum Run Diagnostics. Replace failed
assembly as indicated.
102 - System Board
Failure
None DMA, timers, and so on
Replace the system board. Run
the Compaq System
Configuration Utility.
104 - ASR-2 Timer
Failure
None System board failure
Run Diagnostics. Replace failed
assembly as indicated.
105 - Current System
ROM is corrupt—
now booting
redundant System
ROM
2L Non-booted ROM image is
corrupt
Flash the ROM utilizing
ROMPaq.
162 - System
Options Not Set
2S Configuration incorrect Run the System Configuration
Utility and correct.
163—Time & Date
Not Set
2S Invalid time or date in
configuration memory
Run the System Configuration
Utility and correct.
164 - Memory Size
Error
2S Configuration memory incorrect Run the System Configuration
Utility and correct.
172 - Configuration
Nonvolatile Memory
Invalid
None Nonvolatile configuration corrupt
or jumper installed
Run the System Configuration
Utility and correct.
173 - Slot ID
Mismatch
None Board replaced, configuration not
updated
Run the System Configuration
Utility and correct.
174 - Configuration/
Slot Mismatch Device
Not Found
None PCI board not found Run the System Configuration
Utility and correct.
continued

Table of Contents

Other manuals for Compaq PROLIANT ML370

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq PROLIANT ML370 and is the answer not in the manual?

Compaq PROLIANT ML370 Specifications

General IconGeneral
BrandCompaq
ModelPROLIANT ML370
CategoryServer
LanguageEnglish

Related product manuals